Skip to main navigation Skip to search Skip to main content

Young’s double-slit interference with single hard X-ray photons

Timur Gureyev, Chris J Hall, Benedicta Arhatari, Daniele Pelliccia, Alaleh Aminzadeh, Konstantin M Pavlov, Harry M Quiney

Research output: Contribution to journalArticlepeer-review

4 Citations (Scopus)

Abstract

Double-slit interference experiments using monochromatic hard X-rays with the energy of 25 keV are presented. The experiments were performed at a synchrotron source with a distance of 110 m between the interferometer and the detector to produce an interference pattern with a sufficiently broad period that could be adequately sampled by a photon-counting detector with 75 micrometre pixels. In the single-particle version of the experiment, over one million image frames with a single registered photon in each one were collected. The sum of these frames showed a clear presence of the interference pattern with the expected period. Subsequent analysis provided an objective estimation of the minimal number of detected photons required to determine, in accordance with the Rose criterion, the presence of the photon interference. Apart from a general theoretical interest, these investigations were aimed at exploring the possibility of medical X-ray phase-contrast imaging in photon-counting regime at minimal radiation doses.

Original languageEnglish
Article number19294
Pages (from-to)19294-19307
JournalOptics Express
Volume32
Issue number11
DOIs
Publication statusPublished - 31 Dec 2024

Fingerprint

Dive into the research topics of 'Young’s double-slit interference with single hard X-ray photons'. Together they form a unique fingerprint.

Cite this