Skip to main navigation Skip to search Skip to main content

Reliability and Validity of Sports Accelerometers During Static and Dynamic Testing

Stephen Kelly, Aron Murphy, Mark Watsford, Damien Austin, Michael Rennie

Research output: Contribution to journalArticlepeer-review

48 Citations (Scopus)

Abstract

Purpose: To investigate the validity and reliability of accelerometry of the SPI-ProX II dual data logger (GPSports, Canberra, Australia). Methods: Controlled laboratory assessments determined the accuracy and reproducibility of raw accelerometer data. Intra- and interdevice reliability assessed the ability of the SPI-ProX II accelerometers to repeatedly measure peak gravitational accelerations (g) during impact-based testing. Static and dynamic validity testing assessed the accuracy of SPI-ProX II accelerometers against a criterion-referenced accelerometer. Dynamic validity was assessed over a range of frequencies from 5 to 15 Hz. Results: Intradevice reliability found no differences (P < .05) between 4 SPI-ProX II accelerometers, with a low coefficient of variation (1.87-2.21%). SPI-ProX II accelerometers demonstrated small to medium effect-size (ES) differences (0.10-0.44) between groups and excellent interdevice reliability, with no difference found between units (F = 0.826, P = .484). Validity testing revealed significant differences between devices (P = .001), with high percentage differences (27.5-30.5%) and a large ES (>3.44). Conclusions: SPI-ProX II accelerometers demonstrated excellent intra- and interaccelerometer reliability. However, static and dynamic validity were poor, and caution is recommended when measuring the absolute magnitude of acceleration, particularly for high-frequency movements. Regular assessment of individual devices is advised, particularly for mechanical damage and signal-drift errors. It is recommended that guidelines be provided by the manufacturer on measuring shifts in the base accelerometer signal, including time frames for assessing accelerometer axis, magnitude of errors, and calibration of accelerometers from a stable reference point.
Original languageEnglish
Pages (from-to)106-111
JournalInternational Journal of Sports Physiology and Performance
Volume10
Issue number1
DOIs
Publication statusPublished - 2015

Keywords

  • Biomechanics

Fingerprint

Dive into the research topics of 'Reliability and Validity of Sports Accelerometers During Static and Dynamic Testing'. Together they form a unique fingerprint.

Cite this