Abstract
In this study, two 1/2.2 scaled-down RC exterior joints of a typical Ordinary Moment Resisting Frame (OMRF) were preloaded until moderately cracked and then repaired using a CFRP web-bonded system. The repaired specimens were reloaded under a monotonic load regime. One plain control specimen was also tested in order to compare the results with the repaired specimens under a similar loading condition. The general behaviour of subassemblies was investigated through their beam tip load versus displacement curves. Their available ductilities before and after repair were compared. The results showed that the available ductility of repaired joints, in which ductility is controlled by flexural plastic hinging of members, is limited by the special manner of failure and carbon fibre sheets can relocate the plastic hinges to more favourable locations as well as guaranteeing a ductile behaviour.
| Original language | English |
|---|---|
| Title of host publication | Concrete Solutions: Proceedings of the Second International Conference on Concrete Repair |
| Editors | Michael G Grantham, Rauol Jaubertie, Christophe Lanos |
| Place of Publication | Watford, United Kingdom |
| Publisher | BRE Press |
| Pages | 123-130 |
| ISBN (Print) | 186081915X, 9781860819155 |
| Publication status | Published - 2006 |
| Event | Concrete Solutions 2006: 2nd International Conference on Concrete Repair - St. Malo, France Duration: 27 Jun 2006 → 29 Jun 2006 |
Conference
| Conference | Concrete Solutions 2006: 2nd International Conference on Concrete Repair |
|---|---|
| City | St. Malo, France |
| Period | 27/06/06 → 29/06/06 |
Keywords
- Construction Materials
- Earthquake Engineering
- Infrastructure Engineering and Asset Management
Fingerprint
Dive into the research topics of 'Ductility of FRP-Repaired Exterior RC Beam-Column Joints'. Together they form a unique fingerprint.Cite this